Chimney Safety and Maintenance

Chimney Cleaning Tools and Techniques

Keeping your chimney clean is about more than just aesthetics; its crucial for the safety and efficiency of your fireplace or wood-burning stove. A build-up of creosote, a flammable byproduct of wood combustion, is the primary chimney fire hazard. Regular cleaning removes this risk and allows for proper ventilation, preventing carbon monoxide poisoning.


So, what tools are essential for a thorough chimney cleaning? The most common and effective tool is the chimney brush. These come in various sizes and shapes, including round, square, and oval, to fit different flue dimensions. They're typically made with stiff nylon or wire bristles and attached to flexible rods that can be extended to reach the full length of the chimney. A chimney brush effectively scrapes away creosote and soot.


Beyond the brush, youll need other tools to make the job easier and safer. A drop cloth or plastic sheeting protects your furniture and flooring from soot and debris. A sturdy ladder is essential for roof access, and safety glasses and a dust mask are crucial for protecting your eyes and lungs. A flashlight helps illuminate the inside of the flue, and a chimney scraper can dislodge stubborn creosote deposits. A shop vacuum is useful for cleaning up the fireplace and surrounding area after the cleaning is complete.


As for techniques, there are two main approaches: cleaning from the top down and cleaning from the bottom up. Cleaning from the top down, typically done from the roof, is generally considered more effective as it allows gravity to assist in debris removal. However, its also more dangerous and best left to professionals. Cleaning from the bottom up, using flexible rods pushed up the chimney from the fireplace, is a viable option for DIYers, especially for single-story homes. Regardless of the method, the key is to be thorough and systematic, ensuring the entire flue is cleaned.


Finally, while regular DIY cleaning is possible for some, hiring a certified chimney sweep is often the safest and most effective option. Professionals have the experience, tools, and knowledge to identify potential problems beyond creosote buildup, such as cracks in the flue or nesting animals, ensuring your chimney is safe and ready for use. Remember, a clean chimney is a safe chimney, protecting your home and family from potential hazards.

Chimney Cleaning Tools and Techniques

DIY vs. Professional Chimney Cleaning

Chimney safety is crucial for any homeowner with a fireplace or wood-burning stove. A neglected chimney can become a serious fire hazard, and regular maintenance is essential. One of the biggest decisions homeowners face is whether to tackle chimney cleaning themselves (DIY) or hire a professional. While the DIY route might seem appealing for its cost-saving potential, its a decision that requires careful consideration.


DIY chimney cleaning can be tempting. After all, numerous brush kits are available at hardware stores, and online tutorials make it seem like a manageable task. However, chimney cleaning is more than just pushing a brush down the flue. It requires an understanding of proper techniques, an awareness of potential hazards like creosote buildup, and the ability to identify structural issues like cracks or damage to the flue liner. Without proper training and experience, a DIY attempt can leave creosote deposits behind, increasing the risk of a chimney fire, or even cause damage to the chimney itself. Furthermore, accessing the roof safely requires specific equipment and knowledge, adding another layer of complexity and risk.


Professional chimney sweeps, on the other hand, are trained and equipped to handle all aspects of chimney cleaning and inspection. They have the expertise to identify potential problems, remove creosote effectively, and advise on necessary repairs. They also possess specialized tools, like rotary brushes and powerful vacuums, that can clean more thoroughly than typical DIY kits. This professional approach ensures a safer and more effective cleaning, reducing the risk of chimney fires and extending the life of your chimney. Additionally, many insurance companies require annual inspections by certified professionals to maintain coverage in case of a fire.


Ultimately, while DIY chimney cleaning might seem cost-effective in the short term, the potential risks and limitations often outweigh the benefits. The safety of your home and family should be the priority. Investing in professional chimney cleaning provides peace of mind, knowing that the job is done correctly and thoroughly, protecting your home from potential hazards and ensuring years of safe and enjoyable fires.

Frequency of Chimney Cleaning

Keeping your chimney clean is a crucial part of home safety, and how often you need to do it isnt a one-size-fits-all answer. It really depends on how much you use your fireplace or wood stove, what kind of wood you burn, and even the type of chimney you have.


A good rule of thumb is to have your chimney inspected annually by a certified chimney sweep. They can assess the buildup of creosote, a flammable byproduct of burning wood, and tell you if a cleaning is necessary. Think of it like getting your car checked out – regular maintenance prevents bigger problems down the road.


If youre a heavy user, burning wood several times a week throughout the colder months, youll likely need a yearly cleaning. Moderate users, those who enjoy a cozy fire a few times a week, might be able to stretch it to every other year. Infrequent users, who only light a fire for special occasions, could potentially go three years between cleanings. However, even if you rarely use your fireplace, an annual inspection is still recommended.


The type of wood you burn also plays a role. Softer woods like pine and fir create more creosote than hardwoods like oak and maple. If you primarily burn softwoods, more frequent cleanings will be necessary. Burning unseasoned or wet wood also contributes to creosote buildup.


Finally, the type of chimney you have can influence cleaning frequency. Masonry chimneys tend to accumulate creosote more readily than prefabricated metal chimneys.


Ignoring regular chimney maintenance can lead to chimney fires, which can be devastating. Creosote buildup is highly flammable, and a spark can easily ignite it. Regular cleaning and inspection not only prevent fires but also improve the efficiency of your fireplace or wood stove, allowing it to burn cleaner and produce less smoke. So, while theres no magic number for cleaning frequency, staying informed and getting professional advice will keep your home safe and warm.

Post-Cleaning Inspection and Maintenance

Post-Cleaning Inspection and Maintenance: The Final Touches for a Safe Chimney


A chimney sweeps visit isnt quite the end of the story when it comes to chimney safety. Think of it like a good dental cleaning – you still need to brush and floss at home! After the professionals have done their work, a post-cleaning inspection and ongoing maintenance are crucial for ensuring your chimney remains safe and efficient throughout the year.


Immediately following the cleaning, take a little time to inspect the work. Check that the firebox is free of debris and that the damper opens and closes smoothly. Look around the fireplace hearth and surrounding area for any soot or creosote dust that might have been tracked during the cleaning process. A quick clean-up will prevent this from spreading. It’s also a good idea to visually inspect the chimney exterior, if accessible, for any signs of damage that may have been revealed during the cleaning, like loose bricks or cracks in the mortar.


Beyond the post-cleaning check, regular maintenance is key. Even with professional cleaning, creosote can build up over time. Burning seasoned hardwood and avoiding excessively smoky fires can minimize this, as can using smaller, hotter fires rather than long, smoldering ones. Regularly checking and cleaning the firebox and the area around the damper of ash and debris will also contribute to a safer and more efficient burn.


Finally, remember that an annual inspection by a certified chimney sweep is still essential, even with diligent maintenance. They have the expertise to identify potential problems early on, before they become major safety hazards. Think of it as a yearly check-up for your chimneys health. By combining professional cleaning with post-cleaning inspections and regular maintenance, you can enjoy the warmth and ambiance of your fireplace with peace of mind, knowing you’ve taken the necessary steps to keep your home safe.

The word duct is derived from the Latin word for led/leading. It may refer to:

  • Duct (anatomy), various ducts in anatomy and physiology
  • Duct (HVAC), for transfer of air between spaces in a structure
  • Duct tape, a kind of adhesive tape
  • Ducted fan, motor for aircraft
  • Electrical bus duct, a metal enclosure for busbars
  • Duct (industrial exhaust), industrial exhaust duct system designed for low pressure-pneumatic convey of gas, fumes, dusts, shavings, and other pollutants from works space to atmosphere after cleaning and removal of contaminants
  • Atmospheric duct, a horizontal layer in the lower atmosphere in which the vertical refractive index gradients are such that radio signals (a) are guided or ducted, (b) tend to follow the curvature of the Earth, and (c) experience less attenuation in the ducts than they would if the ducts were not present
  • Surface duct, a sound propagation phenomenon at sea
  • Duct Publishing, an imprint of the German group VDM Publishing devoted to the reproduction of Wikipedia content
  • Dispatchable Unit Control Table (DUCT) in z/Architecture
  • Flexible Ducting

See also

[edit]

A chimney is an architectural ventilation structure made of masonry, clay or metal that isolates hot toxic exhaust gases or smoke produced by a boiler, stove, furnace, incinerator, or fireplace from human living areas. Chimneys are typically vertical, or as near as possible to vertical, to ensure that the gases flow smoothly, drawing air into the combustion in what is known as the stack, or chimney effect. The space inside a chimney is called the flue. Chimneys are adjacent to large industrial refineries, fossil fuel combustion facilities or part of buildings, steam locomotives and ships.

In the United States, the term smokestack industry refers to the environmental impacts of burning fossil fuels by industrial society, including the electric industry during its earliest history. The term smokestack (colloquially, stack) is also used when referring to locomotive chimneys or ship chimneys, and the term funnel can also be used.[1][2]

The height of a chimney influences its ability to transfer flue gases to the external environment via stack effect. Additionally, the dispersion of pollutants at higher altitudes can reduce their impact on the immediate surroundings. The dispersion of pollutants over a greater area can reduce their concentrations and facilitate compliance with regulatory limits.

History

[edit]

Industrial chimney use dates to the Romans, who drew smoke from their bakeries with tubes embedded in the walls. However, domestic chimneys first appeared in large dwellings in northern Europe in the 12th century. The earliest surviving example of an English chimney is at the keep of Conisbrough Castle in Yorkshire, which dates from 1185 AD,[3] but they did not become common in houses until the 16th and 17th centuries.[4] Smoke hoods were an early method of collecting the smoke into a chimney. These were typically much wider than modern chimneys and started relatively high above the fire, meaning more heat could escape into the room. Because the air going up the shaft was cooler, these could be made of less fireproof materials. Another step in the development of chimneys was the use of built-in ovens which allowed the household to bake at home. Industrial chimneys became common in the late 18th century.

Chimneys in ordinary dwellings were first built of wood and plaster or mud. Since then chimneys have traditionally been built of brick or stone, both in small and large buildings. Early chimneys were of simple brick construction. Later chimneys were constructed by placing the bricks around tile liners. To control downdrafts, venting caps (often called chimney pots) with a variety of designs are sometimes placed on the top of chimneys.

In the 18th and 19th centuries, the methods used to extract lead from its ore produced large amounts of toxic fumes. In the north of England, long near-horizontal chimneys were built, often more than 3 km (2 mi) long, which typically terminated in a short vertical chimney in a remote location where the fumes would cause less harm. Lead and silver deposits formed on the inside of these long chimneys, and periodically workers would be sent along the chimneys to scrape off these valuable deposits.[5]

Construction

[edit]
Chimney in NED University

As a result of the limited ability to handle transverse loads with brick, chimneys in houses were often built in a "stack", with a fireplace on each floor of the house sharing a single chimney, often with such a stack at the front and back of the house. Today's central heating systems have made chimney placement less critical, and the use of non-structural gas vent pipe allows a flue gas conduit to be installed around obstructions and through walls.

Chimney in North London
Flue

Most modern high-efficiency heating appliances do not require a chimney. Such appliances are generally installed near an external wall, and a noncombustible wall thimble[clarification needed] allows a vent pipe to run directly through the external wall.

On a pitched roof where a chimney penetrates a roof, flashing is used to seal up the joints. The down-slope piece is called an apron, the sides receive step flashing and a cricket is used to divert water around the upper side of the chimney underneath the flashing.[6]

Industrial chimneys are commonly referred to as flue-gas stacks and are generally external structures, as opposed to those built into the wall of a building. They are generally located adjacent to a steam-generating boiler or industrial furnace and the gases are carried to them with ductwork. Today the use of reinforced concrete has almost entirely replaced brick as a structural element in the construction of industrial chimneys. Refractory bricks are often used as a lining, particularly if the type of fuel being burned generates flue gases containing acids. Modern industrial chimneys sometimes consist of a concrete windshield with a number of flues on the inside.

The 300 m (980 ft) high steam plant chimney at the Secunda CTL's synthetic fuel plant in Secunda, South Africa consists of a 26 m (85 ft) diameter windshield with four 4.6 metre diameter concrete flues which are lined with refractory bricks built on rings of corbels spaced at 10 metre intervals. The reinforced concrete can be cast by conventional formwork or sliding formwork. The height is to ensure the pollutants are dispersed over a wider area to meet legal or other safety requirements.

Residential flue liners

[edit]

A flue liner is a secondary barrier in a chimney that protects the masonry from the acidic products of combustion, helps prevent flue gas from entering the house, and reduces the size of an oversized flue. Since the 1950s, building codes in many locations require newly built chimneys to have a flue liner. Chimneys built without a liner can usually have a liner added, but the type of liner needs to match the type of appliance it services. Flue liners may be clay or concrete tile, metal, or poured in place concrete.

Clay tile flue liners are very common in the United States, although it is the only liner that does not meet Underwriters Laboratories 1777 approval and frequently they have problems such as cracked tiles and improper installation.[7] Clay tiles are usually about 2 feet (0.61 m) long, available in various sizes and shapes, and are installed in new construction as the chimney is built. A refractory cement is used between each tile.

Metal liners may be stainless steel, aluminum, or galvanized iron and may be flexible or rigid pipes. Stainless steel is made in several types and thicknesses. Type 304 is used with firewood, wood pellet fuel, and non-condensing oil appliances, types 316 and 321 with coal, and type AL 29-4C is used with high efficiency condensing gas appliances. Stainless steel liners must have a cap and be insulated if they service solid fuel appliances, but following the manufacturer's instructions carefully.[7] Aluminum and galvanized steel chimneys are known as class A and class B chimneys. Class A are either an insulated, double wall stainless steel pipe or triple wall, air-insulated pipe often known by its genericized trade name Metalbestos. Class B are uninsulated double wall pipes often called B-vent, and are only used to vent non-condensing gas appliances. These may have an aluminum inside layer and galvanized steel outside layer.

Concrete flue liners are like clay liners but are made of a refractory cement and are more durable than the clay liners.

Poured in place concrete liners are made by pouring special concrete into the existing chimney with a form. These liners are highly durable, work with any heating appliance, and can reinforce a weak chimney, but they are irreversible.

Chimney pots, caps, and tops

[edit]

A chimney pot is placed on top of the chimney to expand the length of the chimney inexpensively, and to improve the chimney's draft. A chimney with more than one pot on it indicates that multiple fireplaces on different floors share the chimney.

A cowl is placed on top of the chimney to prevent birds and other animals from nesting in the chimney. They often feature a rain guard to prevent rain or snow from going down the chimney. A metal wire mesh is often used as a spark arrestor to minimize burning debris from rising out of the chimney and making it onto the roof. Although the masonry inside the chimney can absorb a large amount of moisture which later evaporates, rainwater can collect at the base of the chimney. Sometimes weep holes are placed at the bottom of the chimney to drain out collected water.

A chimney cowl or wind directional cap is a helmet-shaped chimney cap that rotates to align with the wind and prevent a downdraft of smoke and wind down the chimney.

An H-style cap is a chimney top constructed from chimney pipes shaped like the letter H. It is an age-old method of regulating draft in situations where prevailing winds or turbulences cause downdraft and back-puffing. Although the H cap has a distinct advantage over most other downdraft caps, it fell out of favor because of its bulky design. It is found mostly in marine use but has been regaining popularity due to its energy-saving functionality. The H-cap stabilizes the draft rather than increasing it. Other downdraft caps are based on the Venturi effect, solving downdraft problems by increasing the updraft constantly resulting in much higher fuel consumption.

A chimney damper is a metal plate that can be positioned to close off the chimney when not in use and prevent outside air from entering the interior space, and can be opened to permit hot gases to exhaust when a fire is burning. A top damper or cap damper is a metal spring door placed at the top of the chimney with a long metal chain that allows one to open and close the damper from the fireplace. A throat damper is a metal plate at the base of the chimney, just above the firebox, that can be opened and closed by a lever, gear, or chain to seal off the fireplace from the chimney. The advantage of a top damper is the tight weatherproof seal that it provides when closed, which prevents cold outside air from flowing down the chimney and into the living space—a feature that can rarely be matched by the metal-on-metal seal afforded by a throat damper. Additionally, because the throat damper is subjected to intense heat from the fire directly below, it is common for the metal to become warped over time, thus further degrading the ability of the throat damper to seal. However, the advantage of a throat damper is that it seals off the living space from the air mass in the chimney, which, especially for chimneys positioned on an outside of wall of the home, is generally very cold. It is possible in practice to use both a top damper and a throat damper to obtain the benefits of both. The two top damper designs currently on the market are the Lyemance (pivoting door) and the Lock Top (translating door).

In the late Middle Ages in Western Europe the design of stepped gables arose to allow maintenance access to the chimney top, especially for tall structures such as castles and great manor houses.

Chimney draught or draft

[edit]

When coal, oil, natural gas, wood, or any other fuel is combusted in a stove, oven, fireplace, hot water boiler, or industrial furnace, the hot combustion product gases that are formed are called flue gases. Those gases are generally exhausted to the ambient outside air through chimneys or industrial flue-gas stacks (sometimes referred to as smokestacks).

The combustion flue gases inside the chimneys or stacks are much hotter than the ambient outside air and therefore less dense than the ambient air. That causes the bottom of the vertical column of hot flue gas to have a lower pressure than the pressure at the bottom of a corresponding column of outside air. That higher pressure outside the chimney is the driving force that moves the required combustion air into the combustion zone and also moves the flue gas up and out of the chimney. That movement or flow of combustion air and flue gas is called "natural draught/draft", "natural ventilation", "chimney effect", or "stack effect". The taller the stack, the more draught or draft is created. There can be cases of diminishing returns: if a stack is overly tall in relation to the heat being sent out of the stack, the flue gases may cool before reaching the top of the chimney. This condition can result in poor drafting, and in the case of wood burning appliances, the cooling of the gases before emission can cause creosote to condense near the top of the chimney. The creosote can restrict the exit of flue gases and may pose a fire hazard.

Designing chimneys and stacks to provide the correct amount of natural draft involves a number of design factors, many of which require iterative trial-and-error methods.

As a "first guess" approximation, the following equation can be used to estimate the natural draught/draft flow rate by assuming that the molecular mass (i.e., molecular weight) of the flue gas and the external air are equal and that the frictional pressure and heat losses are negligible: where:

  • Q = chimney draught/draft flow rate, m3/s
  • A = cross-sectional area of chimney, m2 (assuming it has a constant cross-section)
  • C = discharge coefficient (usually taken to be from 0.65 to 0.70)
  • g = gravitational acceleration, 9.807 m/s2
  • H = height of chimney, m
  • Ti = average temperature inside the chimney, K
  • Te = external air temperature, K.

Combining two flows into chimney: At+Af<A, where At=7.1 inch2 is the minimum required flow area from water heater tank and Af=19.6 inch2 is the minimum flow area from a furnace of a central heating system.

Draft hood

[edit]

Gas fired appliances must have a draft hood to cool combustion products entering the chimney and prevent updrafts or downdrafts.[8][9][10]

Maintenance and problems

[edit]

A characteristic problem of chimneys is they develop deposits of creosote on the walls of the structure when used with wood as a fuel. Deposits of this substance can interfere with the airflow and more importantly, they are combustible and can cause dangerous chimney fires if the deposits ignite in the chimney.

Heaters that burn natural gas drastically reduce the amount of creosote buildup due to natural gas burning much cleaner and more efficiently than traditional solid fuels. While in most cases there is no need to clean a gas chimney on an annual basis that does not mean that other parts of the chimney cannot fall into disrepair. Disconnected or loose chimney fittings caused by corrosion over time can pose serious dangers for residents due to leakage of carbon monoxide into the home.[11] Thus, it is recommended—and in some countries even mandatory—that chimneys be inspected annually and cleaned on a regular basis to prevent these problems. The workers who perform this task are called chimney sweeps or steeplejacks. This work used to be done largely by child labour and, as such, features in Victorian literature. In the Middle Ages in some parts of Europe, a stepped gable design was developed, partly to provide access to chimneys without use of ladders.

Masonry (brick) chimneys have also proven to be particularly prone to crumbling during earthquakes. Government housing authorities in cities prone to earthquakes such as San Francisco, Los Angeles, and San Diego now recommend building new homes with stud-framed chimneys around a metal flue. Bracing or strapping old masonry chimneys has not proven to be very effective in preventing damage or injury from earthquakes. It is now possible to buy "faux-brick" facades to cover these modern chimney structures.

Other potential problems include:

  • "spalling" brick, in which moisture seeps into the brick and then freezes, cracking and flaking the brick and loosening mortar seals.
  • shifting foundations, which may degrade integrity of chimney masonry
  • nesting or infestation by unwanted animals such as squirrels, racoons, or chimney swifts
  • chimney leaks
  • drafting issues, which may allow smoke inside building[12]
  • issues with fireplace or heating appliance may cause unwanted degradation or hazards to chimney

Chimneys of special interest

[edit]

Chimneys with observation decks

[edit]

Several chimneys with observation decks were built. The following possibly incomplete list shows them.

Name Country Town Coordinates Year of completion Total height Height of observation deck Remarks
Chimney of Beitou Refuse Incineration Plant Taiwan Teipei 25°06′29″N 121°29′58″E / 25.108043°N 121.499384°E / 25.108043; 121.499384 (Chimney of Beitou Refuse Incineration Plant) 2000 150 m (492 ft) 116 m (381 ft) revolving restaurant in a height of 120 metres (394 ft)
Radio City Tower United Kingdom Liverpool   53°24′23″N 2°58′55″W / 53.406332°N 2.982002°W / 53.406332; -2.982002 (Radio City Tower) 1971 148 m (486 ft) 124.7 m (409 ft) chimney for the heating system of a nearby mall
Large Chimney of Warsaw Refuse Incineration Plant Poland Warsaw   52°15′41″N 21°06′18″E / 52.261448°N 21.105072°E / 52.261448; 21.105072 (Large Chimney of Warsaw Refuse Incineration Plant) 2024 72 m (236 ft)   observation deck only accessible at guided tours through the facility
Bernard Brewery Chimney Czech Humpolec   49°32′23″N 15°21′36″E / 49.539786°N 15.360043°E / 49.539786; 15.360043 (Bernard Brewery Chimney)   40.7 m (134 ft) 33 m (108 ft) observation deck added in 2020/21
Dům DÄ›tí a Mládeže v ModÃ…â„¢anech Czech Prague   50°00′44″N 14°24′49″E / 50.012154°N 14.413657°E / 50.012154; 14.413657 (Dům DÄ›tí a Mládeže v ModÃ…â„¢anech) 2004 15 m (49 ft) 12 m (39 ft) observation platform on chimney of the roof of a youth centre
Chimney of Zenner Heating Building Germany Berlin   52°29′17″N 13°28′38″E / 52.488097°N 13.477282°E / 52.488097; 13.477282 (Chimney of Zenner Heating Building) 1955 15 m (49 ft) 12 m (39 ft) perhaps never in use as observation tower

Chimneys used as electricity pylon

[edit]

At several thermal power stations at least one smokestack is used as electricity pylon. The following possibly incomplete list shows them.

Country City Coordinates Name Height Year of construction Voltage Remarks
Germany Gelsenkirchen   51°36′02″N 7°00′16″E / 51.600623°N 7.004573°E / 51.600623; 7.004573 (Scholven Power Station, Chimney for Units B, C, D and E) Scholven Power Station, Chimney for Units B, C, D and E 300 m   220 kV  
Belarus Novolukoml   54°40′45″N 29°08′09″E / 54.679048°N 29.135925°E / 54.679048; 29.135925 (Lukoml Power Station, Chimney 1) Lukoml Power Station, Chimney 1 250 m 1969 330 kV  
Belarus Novolukoml   54°40′48″N 29°08′07″E / 54.679941°N 29.135259°E / 54.679941; 29.135259 (Lukoml Power Station, Chimney 2) Lukoml Power Station, Chimney 2 250 m 1971 330 kV  
Belarus Novolukoml   54°40′53″N 29°08′04″E / 54.681290°N 29.134428°E / 54.681290; 29.134428 (Lukoml Power Station, Chimney 3) Lukoml Power Station, Chimney 3 250 m 1973 330 kV  
Lithuania Elektrenai   54°46′17″N 24°38′50″E / 54.771463°N 24.647291°E / 54.771463; 24.647291 (ElektrÄ—nai Power Plant, Chimney 1) ElektrÄ—nai Power Plant, Chimney 1 150 m   330 kV dismantled
Lithuania Elektrenai   54°46′12″N 24°38′48″E / 54.770110°N 24.646765°E / 54.770110; 24.646765 (ElektrÄ—nai Power Plant, Chimney 2) ElektrÄ—nai Power Plant, Chimney 2 250 m   330 kV dismantled
Moldova Dnestrovsc   46°37′40″N 29°56′23″E / 46.627864°N 29.939691°E / 46.627864; 29.939691 (Cuciurgan power station, Chimney 1) Cuciurgan power station, Chimney 1 180 m 1964 110 kV  
Moldova Dnestrovsc   46°37′44″N 29°56′23″E / 46.628880°N 29.939622°E / 46.628880; 29.939622 (Cuciurgan power station, Chimney 2) Cuciurgan power station, Chimney 2 180 m 1966 330 kV  
Moldova Dnestrovsc   46°37′49″N 29°56′23″E / 46.630199°N 29.939622°E / 46.630199; 29.939622 (Cuciurgan power station, Chimney 3) Cuciurgan power station, Chimney 3 180 m 1971 330 kV  
Russia Archangelsk   64°34′29″N 40°34′24″E / 64.574788°N 40.573261°E / 64.574788; 40.573261 (Archangelsk Cogeneration Plant, Chimney 1) Archangelsk Cogeneration Plant, Chimney 1 170 m   220 kV  
Russia Saint Petersburg   59°58′14″N 30°22′35″E / 59.970595°N 30.376425°E / 59.970595; 30.376425 (Vyborgskaya Cogenaration Plant, Chimney 1) Vyborgskaya Cogenaration Plant, Chimney 1 120 m   110 kV  
Russia Tobolsk   58°14′44″N 68°26′43″E / 58.245439°N 68.445224°E / 58.245439; 68.445224 (Tobolsk Cogeneration Plant, Chimney 1) TEC Tobolsk, Chimney 1 240 m 1980 110 kV  
Russia Tobolsk   58°14′45″N 68°26′55″E / 58.245781°N 68.448590°E / 58.245781; 68.448590 (Tobolsk Cogeneration Plant, Chimney 2) TEC Tobolsk, Chimney 2 270 m 1986 220 kV  
Russia Kashira   54°51′24″N 38°15′23″E / 54.856639°N 38.256428°E / 54.856639; 38.256428 (Kashira Power Plant, Chimney 1) Kashira Power Plant, Chimney 1 250 m 1966 220 kV  
Russia Energetik   51°45′12″N 58°48′09″E / 51.753324°N 58.802583°E / 51.753324; 58.802583 (Iriklinskaya Power Station, Chimney 1) Iriklinskaya Power Station, Chimney 1 180 m   220 kV  
Russia Energetik   51°45′12″N 58°48′14″E / 51.753453°N 58.803983°E / 51.753453; 58.803983 (Iriklinskaya Power Station, Chimney 2) Iriklinskaya Power Station, Chimney 2 180 m   220 kV  
Russia Energetik   51°45′13″N 58°48′22″E / 51.753483°N 58.806183°E / 51.753483; 58.806183 (Iriklinskaya Power Station, Chimney 3) Iriklinskaya Power Station, Chimney 3 250 m   500 kV  
Russia Konakovo   56°44′23″N 36°46′22″E / 56.739703°N 36.772833°E / 56.739703; 36.772833 (Konakovo Power Station, Chimney 1) Konakovo Power Station, Chimney 1 180 m 1964 220 kV  
Russia Konakovo   56°44′26″N 36°46′20″E / 56.740627°N 36.772308°E / 56.740627; 36.772308 (Konakovo Power Station, Chimney 2) Konakovo Power Station, Chimney 2 180 m 1966 220 kV  
Russia Koryazhma   61°18′09″N 47°07′13″E / 61.302456°N 47.120396°E / 61.302456; 47.120396 (Chimney 1 of Cogenaration Plant 1 of Kotlas Pulp and Paper Mill) Chimney 1 of Cogenaration Plant 1 of Kotlas Pulp and Paper Mill 105 m 1961 220 kV  
Ukraine Burshtyn   49°12′27″N 24°40′03″E / 49.207578°N 24.667450°E / 49.207578; 24.667450 (Burshtyn Power Station, Chimney 1) Burshtyn Power Station, Chimney 1 180 m 1965 330 kV  
Ukraine Burshtyn   49°12′31″N 24°39′57″E / 49.208595°N 24.665921°E / 49.208595; 24.665921 (Burshtyn Power Station, Chimney 2) Burshtyn Power Station, Chimney 2 250 m 1966 330 kV  
Ukraine Burshtyn   49°12′34″N 24°39′54″E / 49.209334°N 24.664918°E / 49.209334; 24.664918 (Burshtyn Power Station, Chimney 3) Burshtyn Power Station, Chimney 3 250 m 1966 330 kV  
Ukraine Trypillia   50°08′01″N 30°44′52″E / 50.133591°N 30.747659°E / 50.133591; 30.747659 (Trypillia Power Station, Chimney 1) Trypillia Power Station, Chimney 1 180 m 1968 330 kV  
Ukraine Trypillia   50°08′00″N 30°44′44″E / 50.133239°N 30.745553°E / 50.133239; 30.745553 (Trypillia Power Station, Chimney 2) Trypillia Power Station, Chimney 2 180 m 1972 330 kV  

Nearly all this structures exist in an area, which was once part of the Soviet Union. Although this use has the disadvantage that conductor ropes may corrode faster due to the exhaust gases, one can find such structures also sometimes in countries not influenced by the former Soviet Union. An example herefore is one chimney of Scholven Power Plant in Gelsenkirchen, which carries one circuit of an outgoing 220 kV-line.

Chimneys used as water tower

[edit]

Chimneys can also carry a water tank on their structure. This combination has the advantage that the warm smoke running through the chimney prevents the water in the tank from freezing. Before World War II such structures were not uncommon, especially in countries influenced by Germany.

Chimneys used as radio tower

[edit]

Chimneys can carry antennas for radio relay services, cell phone transmissions, FM-radio and TV on their structure. Also long wire antennas for mediumwave transmissions can be fixed at chimneys. In all cases it had to be considered that these objects can easily corrode especially when placed near the exhaust. Sometimes chimneys were converted into radio towers and are not useable as ventilation structure any more.

Chimneys used for advertising

[edit]

As chimneys are often the tallest part of a factory, they offer the possibility as advertising billboard either by writing the name of the company to which they belong on the shaft or by installing advertisement boards on their structure.

Cooling tower used as an industrial chimney

[edit]

At some power stations, which are equipped with plants for the removal of sulfur dioxide and nitrogen oxides, it is possible to use the cooling tower as a chimney. Such cooling towers can be seen in Germany at the Großkrotzenburg Power Station and at the Rostock Power Station. At power stations that are not equipped for removing sulfur dioxide, such usage of cooling towers could result in serious corrosion problems which are not easy to prevent.

See also

[edit]

References

[edit]
  1. ^ C.F. Saunders (1923), The Southern Sierras of California
  2. ^ "Jules Verne (1872), Around the World in Eighty Days". Retrieved 2006-07-30.
  3. ^ James Burke, Connections (Little, Brown and Co.) 1978/1995, ISBN 0-316-11672-6, p. 159
  4. ^ Sparrow, Walter Shaw. The English house: how to judge its periods and styles. London: Eveleigh Nash, 1908. 85–86.
  5. ^ "Lead Mining". The Northern Echo. Newsquest Media Group. Retrieved 10 April 2012.
  6. ^ Roofing, flashing & waterproofing. Newtown, CT: Taunton Press, 2005. 43–50.
  7. ^ a b Bliss, Stephen, ed.. Troubleshooting guide to residential construction: the diagnosis and prevention of common building problems. Richmond, VT: Builderburg Group, 1997. 197. Print.
  8. ^ "Field Installation of Draft Hoods" (PDF). A.O. Smith Water Products Company. 2009. Retrieved January 6, 2016.
  9. ^ "Guide to Draft Hoods on Gas Fired Heating Equipment". InspectApedia.com. 2017. Retrieved January 6, 2016.
  10. ^ Reuben Saltzman (September 24, 2013). "Water Heater Backdrafting, Part 1 of 2: Why it Matters and What to Look For". Structure Tech. Retrieved January 6, 2016.
  11. ^ Chimney Problems and Warnings Signs
  12. ^ "Chimney Airflow Problems". 8 June 2022.
[edit]

 

An American style clothes dryer with a rear control panel
A European style clothes dryer with a front control panel
A Japanese style combi washer-dryer
A German spin dryer in use

A clothes dryer (tumble dryer, drying machine, or simply dryer) is a powered household appliance that is used to remove moisture from a load of clothing, bedding and other textiles, usually after they are washed in the washing machine.

Many dryers consist of a rotating drum called a "tumbler" through which heated air is circulated to evaporate moisture while the tumbler is rotated to maintain air space between the articles. Using such a machine may cause clothes to shrink or become less soft (due to loss of short soft fibers). A simpler non-rotating machine called a "drying cabinet" may be used for delicate fabrics and other items not suitable for a tumble dryer. Other machines include steam to de-shrink clothes and avoid ironing.[1]

Tumble dryers

[edit]

Tumble dryers continuously draw in the ambient air around them and heat it before passing it through the tumbler. The resulting hot, humid air is usually vented outside to make room for more air to continue the drying process.

Tumble dryers are sometimes integrated with a washing machine, in the form of washer-dryer combos, which are essentially a front loading washing machine with an integrated dryer or (in the US) a laundry center, which stacks the dryer on top of the washer and integrates the controls for both machines into a single control panel. Often the washer and dryer functions will have a different capacity, with the dryer usually having a lower capacity than the washer. Tumble dryers can also be top loading, in which the drum is loaded from the top of the machine and the drum's end supports are in the left and right sides, instead of the more conventional front and rear. They can be as thin as 40 centimetres (16 in) in width, and may include detachable stationary racks for drying items like plush toys and footwear.[2]

Ventless dryers

[edit]

Spin dryers

[edit]
Spin dryer type TS66

These centrifuge machines simply spin their drums much faster than a typical washer could, in order to extract additional water from the load. They may remove more water in two minutes than a heated tumble dryer can in twenty, thus saving significant amounts of time and energy. Although spinning alone will not completely dry clothing, this additional step saves a worthwhile amount of time and energy for large laundry operations such as those of hospitals.

Condenser dryers

[edit]

Just as in a tumble dryer, condenser or condensation dryers pass heated air through the load. However, instead of exhausting this air, the dryer uses a heat exchanger to cool the air and condense the water vapor into either a drain pipe or a collection tank. The drier air is run through the loop again. The heat exchanger typically uses ambient air as its coolant, therefore the heat produced by the dryer will go into the immediate surroundings instead of the outside, increasing the room temperature. In some designs, cold water is used in the heat exchanger, eliminating this heating, but requiring increased water usage.

In terms of energy use, condenser dryers typically require around 2 kilowatt hours (kW⋅h) of energy per average load.[3]

Because the heat exchange process simply cools the internal air using ambient air (or cold water in some cases), it will not dry the air in the internal loop to as low a level of humidity as typical fresh, ambient air. As a consequence of the increased humidity of the air used to dry the load, this type of dryer requires somewhat more time than a tumble dryer. Condenser dryers are a particularly attractive option where long, intricate ducting would be required to vent the dryer.

Heat pump dryers

[edit]

A closed-cycle heat pump clothes dryer uses a heat pump to dehumidify the processing air. Such dryers typically use under half the energy per load of a condenser dryer.

Whereas condensation dryers use a passive heat exchanger cooled by ambient air, these dryers use a heat pump. The hot, humid air from the tumbler is passed through a heat pump where the cold side condenses the water vapor into either a drain pipe or a collection tank and the hot side reheats the air afterward for re-use. In this way not only does the dryer avoid the need for ducting, but it also conserves much of its heat within the dryer instead of exhausting it into the surroundings. Heat pump dryers can, therefore, use up to 50% less energy required by either condensation or conventional electric dryers. Heat pump dryers use about 1 kW⋅h of energy to dry an average load instead of 2 kW⋅h for a condenser dryer, or from 3 to 9 kW⋅h, for a conventional electric dryer.[4][5][3] Domestic heat pump dryers are designed to work in typical ambient temperatures from 5 to 30 °C (41 to 86 °F). Below 5 °C (41 °F), drying times significantly increase.

As with condensation dryers, the heat exchanger will not dry the internal air to as low a level of humidity as the typical ambient air. With respect to ambient air, the higher humidity of the air used to dry the clothes has the effect of increasing drying times; however, because heat pump dryers conserve much of the heat of the air they use, the already-hot air can be cycled more quickly, possibly leading to shorter drying times than tumble dryers, depending on the model.

Mechanical steam compression dryers

[edit]

A new type of dryer in development, these machines are a more advanced version of heat pump dryers. Instead of using hot air to dry the clothing, mechanical steam compression dryers use water recovered from the clothing in the form of steam. First, the tumbler and its contents are heated to 100 °C (212 °F). The wet steam that results purges the system of air and is the only remaining atmosphere in the tumbler.

As wet steam exits the tumbler, it is mechanically compressed (hence the name) to extract water vapor and transfer the heat of vaporization to the remaining gaseous steam. This pressurized, gaseous steam is then allowed to expand, and is superheated before being injected back into the tumbler where its heat causes more water to vaporize from the clothing, creating more wet steam and restarting the cycle.

Like heat pump dryers, mechanical steam compression dryers recycle much of the heat used to dry the clothes, and they operate in a very similar range of efficiency as heat pump dryers. Both types can be over twice as efficient as conventional tumble dryers. The considerably higher temperatures used in mechanical steam compression dryers result in drying times on the order of half as long as those of heat pump dryers.[6]

Convectant drying

[edit]

Marketed by some manufacturers as a "static clothes drying technique", convectant dryers simply consist of a heating unit at the bottom, a vertical chamber, and a vent at top. The unit heats air at the bottom, reducing its relative humidity, and the natural tendency of hot air to rise brings this low-humidity air into contact with the clothes. This design is slower than conventional tumble dryers, but relatively energy-efficient if well-implemented. It works particularly well in cold and humid environments, where it dries clothes substantially faster than line-drying. In hot and dry weather, the performance delta over line-drying is negligible.

Given that this is a relatively simple and cheap technique to materialize, most consumer products showcase the added benefit of portability and/or modularity. Newer designs implement a fan heater at the bottom to pump hot air into the vertical drying rack chamber. Temperatures in excess of 60 °C (140 °F) can be reached inside these "hot air balloons," yet lint, static cling, and shrinkage are minimal. Upfront cost is significantly lower than tumble, condenser and heat pump designs.

If used in combination with washing machines featuring fast spin cycles (800+ rpm) or spin dryers, the cost-effectiveness of this technique has the potential to render tumble dryer-like designs obsolete in single-person and small family households. One disadvantage is that the moisture from the clothes is released into the immediate surroundings. Proper ventilation or a complementary dehumidifier is recommended for indoor use. It also cannot compete with the tumble dryer's capacity to dry multiple loads of wet clothing in a single day.

Solar clothes dryer

[edit]

The solar dryer is a box-shaped stationary construction which encloses a second compartment where the clothes are held. It uses the sun's heat without direct sunlight reaching the clothes. Alternatively, a solar heating box may be used to heat air that is driven through a conventional tumbler dryer.

Microwave dryers

[edit]

Japanese manufacturers[7] have developed highly efficient clothes dryers that use microwave radiation to dry the clothes (though a vast majority of Japanese air dry their laundry). Most of the drying is done using microwaves to evaporate the water, but the final drying is done by convection heating, to avoid problems of arcing with metal pieces in the laundry.[8][9] There are a number of advantages: shorter drying times (25% less),[10] energy savings (17–25% less), and lower drying temperatures. Some analysts think that the arcing and fabric damage is a factor preventing microwave dryers from being developed for the US market.[11][12]

Ultrasonic dryers

[edit]

Ultrasonic dryers use high-frequency signals to drive piezoelectric actuators in order to mechanically shake the clothes, releasing water in the form of a mist which is then removed from the drum. They have the potential to significantly cut energy consumption while needing only one-third of the time needed by a conventional electric dryer for a given load.[13] They also do not have the same issues related with lint in most other types of dryers.[14]

Hybrid dryers

[edit]

Some manufacturers, like LG Electronics and Whirlpool, have introduced hybrid dryers, that offer the user the option of using either a heat pump or a traditional electric heating element for drying the user's clothes. Hybrid dryers can also use a heat pump and a heating element at the same time to dry clothes faster.

Static electricity

[edit]

Clothes dryers can cause static cling through the triboelectric effect. This can be a minor nuisance and is often a symptom of over-drying textiles to below their equilibrium moisture level, particularly when using synthetic materials. Fabric conditioning products such as dryer sheets are marketed to dissipate this static charge, depositing surfactants onto the fabric load by mechanical abrasion during tumbling.[15] Modern dryers often have improved temperature and humidity sensors and electronic controls which aim to stop the drying cycle once textiles are sufficiently dry, avoiding over-drying and the static charge and energy wastage this causes.

Pest control use

[edit]

Drying at a minimum of 60 °C (140 °F) heat for thirty minutes kills many parasites including house dust mites,[16] bed bugs,[17] and scabies mites[18] and their eggs; a bit more than ten minutes kills ticks.[19] Simply washing drowns dust mites, and exposure to direct sunlight for three hours kills their eggs.[16]

Lint build-up (tumble dryers)

[edit]
Upper image shows a severely kinked and blocked dryer transition hose used to vent a tumble dryer. In this case, the dryer was located or pushed back too far against the wall. The lower image shows initial lint build-up in the flex transition hose.

Moisture and lint are byproducts of the tumble drying process and are pulled from the drum by a fan motor and then pushed through the remaining exhaust conduit to the exterior termination fitting. Typical exhaust conduit comprises flex transition hose found immediately behind the dryer, the 4-inch (100 mm) rigid galvanized pipe and elbow fittings found within the wall framing, and the vent duct hood found outside the house.

A clean, unobstructed dryer vent improves both the efficiency and safety of the dryer. As the dryer duct pipe becomes partially obstructed and filled with lint, drying time markedly increases and causes the dryer to waste energy. A blocked vent increases the internal temperature and may result in a fire. Clothes dryers are one of the more costly home appliances to operate.[20]

Several factors can contribute to or accelerate rapid lint build-up. These include long or restrictive ducts, bird or rodent nests in the termination, crushed or kinked flex transition hose, terminations with screen-like features, and condensation within the duct due to un-insulated ducts traveling through cold spaces such as a crawl space or attic. If plastic flaps are at the outside end of the duct, one may be able to flex, bend, and temporarily remove the plastic flaps, clean the inside surface of the flaps, clean the last foot or so of the duct, and reattach the plastic flaps. The plastic flaps keep insects, birds, and snakes[21] out of the dryer vent pipe. During cold weather, the warm wet air condenses on the plastic flaps, and minor trace amounts of lint sticks to the wet inside part of the plastic flaps at the outside of the building.[22][23]

Home clothes dryer outside vent outlet. Flaps on the duct can be removed for cleaning of the flaps and the duct.

Ventless dryers include multi-stage lint filtration systems and some even include automatic evaporator and condenser cleaning functions that can run even while the dryer is running. The evaporator and condenser are usually cleaned with running water. These systems are necessary, in order to prevent lint from building up inside the dryer and evaporator and condenser coils.

Aftermarket add-on lint and moisture traps can be attached to the dryer duct pipe, on machines originally manufactured as outside-venting, to facilitate installation where an outside vent is not available. Increased humidity at the location of installation is a drawback to this method.[24]

Safety

[edit]

Dryers expose flammable materials to heat. Underwriters Laboratories[25] recommends cleaning the lint filter after every cycle for safety and energy efficiency, provision of adequate ventilation, and cleaning of the duct at regular intervals.[26] UL also recommends that dryers not be used for glass fiber, rubber, foam or plastic items, or any item that has had a flammable substance spilled on it.

A white clothes dryer with charred sides sitting outdoors on pavement
A clothes dryer that has been damaged by fire

In the United States, an estimate from the US Fire Administration[27] in a 2012 report estimated that from 2008 to 2010, fire departments responded to an estimated 2,900 clothes dryer fires in residential buildings each year across the nation. These fires resulted in an annual average loss of 5 deaths, 100 injuries, and $35 million in property loss. The Fire Administration attributes "Failure to clean" (34%) as the leading factor contributing to clothes dryer fires in residential buildings, and observed that new home construction trends place clothes dryers and washing machines in more hazardous locations away from outside walls, such as in bedrooms, second-floor hallways, bathrooms, and kitchens.

To address the problem of clothes dryer fires, a fire suppression system can be used with sensors to detect the change in temperature when a blaze starts in a dryer drum. These sensors then activate a water vapor mechanism to put out the fire.[28]

Environmental impact

[edit]

The environmental impact of clothes dryers is especially severe in the US and Canada, where over 80% of all homes have a clothes dryer. According to the US Environmental Protection Agency, if all residential clothes dryers sold in the US were energy efficient, "the utility cost savings would grow to more than $1.5 billion each year and more than 10 billion kilograms (22 billion pounds) of annual greenhouse gas emissions would be prevented”.[29]

Clothes dryers are second only to refrigerators and freezers as the largest residential electrical energy consumers in America.[30]

In the European Union, the EU energy labeling system is applied to dryers; dryers are classified with a label from A+++ (best) to G (worst) according to the amount of energy used per kilogram of clothes (kW⋅h/kg). Sensor dryers can automatically sense that clothes are dry and switch off. This means over-drying is not as frequent. Most of the European market sells sensor dryers now, and they are normally available in condenser and vented dryers.

History

[edit]

A hand-cranked clothes dryer was created in 1800 by M. Pochon from France.[31] Henry W. Altorfer invented and patented an electric clothes dryer in 1937.[32] J. Ross Moore, an inventor from North Dakota, developed designs for automatic clothes dryers and published his design for an electrically operated dryer in 1938.[33] Industrial designer Brooks Stevens developed an electric dryer with a glass window in the early 1940s.[34]

See also

[edit]

References

[edit]
  1. ^ "How can you wash and dry clothes with steam?". 30 June 2008. Retrieved June 30, 2008.
  2. ^ "Using the Dryer Rack - LG Dryer | LG USA Support". LG USA.
  3. ^ a b "Miele TDA 140 C T Classic condenser tumble dryer". m.miele.co.uk. Archived from the original on 29 October 2018. Retrieved 4 April 2018.
  4. ^ "Miele TDB120WP Eco T1 Classic heat-pump tumble dryer". m.miele.co.uk. Archived from the original on 19 February 2018. Retrieved 4 April 2018.
  5. ^ "Clothes Dryer Energy Use - Running Costs Explained – Canstar Blue". canstarblue.com.au. 3 July 2017. Retrieved 4 April 2018.
  6. ^ "Archived copy" (PDF). Archived from the original (PDF) on 2011-07-20. Retrieved 2010-11-06.cite web: CS1 maint: archived copy as title (link)
  7. ^ "衣類乾燥機".
  8. ^ "Popular Science". October 1994.
  9. ^ "Fabric dryer with arcing avoidance system".
  10. ^ "Flex Your Power - Residential Product Guides". 6 March 2012. Archived from the original on 6 March 2012. Retrieved 4 April 2018.
  11. ^ Gerling, J. Microwave Clothes Drying – Technical Solutions to a Fundamental Challenges. Appliance Magazine, Apr 2003. http://www.appliancemagazine.com/editorial.php?article=150&zone=first=1 Archived 2014-05-24 at the Wayback Machine
  12. ^ Levy, Clifford J. (September 15, 1991). "Tech Notes; Using Microwaves to Dry Clothes". The New York Times.
  13. ^ Mueller, Mike (2017-04-12). "No Heat? No Problem: This Ultrasonic Dryer Dries Clothes in Half the Time". Office of Energy Efficiency & Renewable Energy. Archived from the original on 2017-04-18. Retrieved 2021-06-09.
  14. ^ Momem, Ayyoub M. "Novel Ultra-Low-Energy Consumption Ultrasonic Clothes Dryer". United States Department of Energy. Retrieved 20 April 2017.
  15. ^ Jones, C. R.; Corona, A.; Amador, C.; Fryer, P. J. (2022-07-15). "Dynamics of fabric and dryer sheet motion in domestic clothes dryers". Drying Technology. 40 (10): 2087–2104. doi:10.1080/07373937.2021.1918706. ISSN 0737-3937. S2CID 236596597.
  16. ^ a b Mahakittikun, V; Boitano, JJ; Ninsanit, P; Wangapai, T; Ralukruedej, K (December 2011). "Effects of high and low temperatures on development time and mortality of house dust mite eggs". Experimental & Applied Acarology. 55 (4): 339–47. doi:10.1007/s10493-011-9480-2. PMID 21751035.
  17. ^ Ibrahim, O; Syed, UM; Tomecki, KJ (March 2017). "Bedbugs: Helping your patient through an infestation". Cleveland Clinic Journal of Medicine. 84 (3): 207–211. doi:10.3949/ccjm.84a.15024. PMID 28322676.
  18. ^ Prevention, CDC-Centers for Disease Control and (April 19, 2019). "CDC - Scabies - Treatment". CDC.gov.
  19. ^ Schlanger, Zoë (27 May 2020). "Lyme Disease Season Is Here. These Are Tips on How to Avoid It". The New York Times.
  20. ^ Home Appliance Energy Use, General Electric, archived from the original on 2010-08-22, retrieved 2010-08-23
  21. ^ Didlake, Brian (March 24, 2021). "'There's a dead snake in there:' Florida family finds serpent snarled up in dryer". WKMG.
  22. ^ "Technical Product Specifications | Deflect-O" (PDF). www.deflecto.com. Archived from the original (PDF) on 9 May 2015.
  23. ^ "Technical Product Specifications | Deflect-O Hardware" (PDF). www.deflecto.com. Archived from the original (PDF) on 9 May 2015.
  24. ^ superacademy (2022-11-17). "Dryer Vent Safety and Tips -". Retrieved 2023-10-13.
  25. ^ "Underwriters Laboratories". Archived from the original on 2008-02-22. Retrieved 2008-02-13.
  26. ^ Underwriters Laboratories product safety tips - clothes dryers Archived 2014-03-05 at the Wayback Machine.
  27. ^ "Clothes Dryer Fires in Residential Buildings (2008-2010)" (PDF). FEMA.
  28. ^ careinfo.org Archived 2011-10-20 at the Wayback Machine, New S.A.F.E. system tackles safety problem of fires in laundry dryers Archived 2017-05-01 at the Wayback Machine , November 2001. Accessed 10 October 2011.
  29. ^ "EPA adds clothes dryers to Energy Star program". Press release EPA
  30. ^ "Emerging Technologies: A Case Study of the Super Efficient Dryers Initiative". ACEEE.org
  31. ^ Binggeli, Corky (2003). Building Systems for Interior Designers. Wiley. p. 264. ISBN 978-0-471-41733-0. Retrieved 2009-10-04.
  32. ^ "Patent US2137376A". Google Patents.
  33. ^ Acton, Johnny; Adams, Tania; Packer, Matt (2006). The origin of everyday things. New York: Sterling. pp. 247. ISBN 1402743025.
  34. ^ Brooks Stevens, Wisconsin Historical Society, archived from the original on 2017-09-26, retrieved 2009-10-04
[edit]

 

Driving Directions in


Driving Directions From Apple Natick to
Driving Directions From The Container Store to
Driving Directions From Everything But Water to
Driving Directions From Hampton Inn Boston/Natick to
Driving Directions From Vera Bradley to
Driving Directions From Urban Outfitters to
Driving Directions From Ann Taylor to
Driving Directions From Red Roof PLUS+ Boston - Framingham to
Driving Directions From New Brunswick Graffiti Gallery to
Driving Directions From Boyd Park to
Driving Directions From Cornelius Low House to
Driving Directions From Kearny Cottage Museum to
Driving Directions From Jamesburg Park to
Driving Directions From Raritan Bay Waterfront Park to
Driving Directions From Plainsboro Preserve to
Driving Directions From Old Bridge Waterfront Park to
View GBP

Driving Directions in Middlesex County


Driving Directions From 42.283689911374, -71.3546471598 to
Driving Directions From 42.307622192333, -71.33448547954 to
Driving Directions From 42.293294579704, -71.346430763649 to
Driving Directions From 42.268498889654, -71.333111067988 to
Driving Directions From 42.267883428868, -71.436509870064 to
Driving Directions From 42.239351080121, -71.464660145191 to
Driving Directions From 42.228125666134, -71.446186952473 to
Driving Directions From 42.327559856222, -71.35051616713 to
Driving Directions From 42.314795180885, -71.313667322251 to
Driving Directions From 42.263618669661, -71.32532156694 to
It depends on usage, but at least once a year is recommended, especially before the heating season. More frequent cleanings may be necessary if you burn a lot of wood or have a fireplace insert.
A dirty chimney can lead to chimney fires from creosote buildup and carbon monoxide poisoning due to blockages. It can also reduce heating efficiency.